Inability to identify variations in the inferior epigastric vessels may make them more vulnerable to vascular injury during laparoscopy port insertion. Their relationship with post-operative port-site complications, however, has not been sufficiently explored. Objective: To assess the association between anatomical variations of the inferior epigastric vessels and port-site complications following laparoscopic abdominal surgery. Methods: A cross-sectional study was designed, with a comparison between 151 adult patients who were undergoing elective abdominal surgery under laparoscopy at DHQ Hospital Muzaffar Garh. Consecutive sampling was used for selecting participants. Color Doppler ultrasonography was used to evaluate the inferior epigastric vascular anatomy. Any intraoperative and postoperative port-site complications were documented. Associations were evaluated using appropriate statistical tests and multivariable logistic regression. Results: In the present study, anatomical variations were associated with increased odds of port-site complications (aOR = 3.42; 95% CI: 1.21–9.67; p = 0.020). Body mass index (aOR = 1.12; p = 0.034) and lateral trocar placement (aOR = 2.76; p = 0.042) also had significant associations. The complication rates did not differ significantly by age, sex, or surgery type. Conclusion: Anatomical variations of the inferior epigastric vessels may be associated with port-site morbidity following laparoscopic abdominal surgery. Further research is needed to establish the safety of surgery through individual assessment of the vascularity and careful placement of the trocars.
The minimally invasive nature of the procedure, as well as the fact that its postoperative period is characterized by a lesser degree of pain, is shorter in length than that of open surgery, and the time of recovery is shorter, has led to the use of laparoscopic abdominal surgery in modern surgical practice.[1] Despite these benefits, the insertion of the trocar is still a key step that has been linked with disruption of the vascular structures, especially the inferior epigastric vessels. These are significant blood supply vessels and should be avoided at the time of secondary laparoscopic port placement.[2] In 2021, an extensive review was published reporting that 48% (95% CI: 40–55%) of all vascular injuries were described in inferior epigastric vessels in laparoscopic and robotic-assisted procedures.[3] These injuries can lead to port-site bleeding, abdominal
wall hematoma, postoperative pain, and even substantial bleeding that requires surgical intervention.[4]
The inferior epigastric artery usually runs on the back of the rectus abdominis muscle and, with its veins, travels from the external iliac artery at the level of the inguinal ligament.[5] There is a lot of anatomical variation, however, in the course, branching pattern, lateral displacement, and relationship of these vessels to known abdominal landmarks.[6] In a recent anatomical mapping review published in 2026, significant anatomical variations in the distance of the inferior epigastric artery from the abdominal midline were found, with interstudy distances from the abdominal midline reported by different studies from 3 to 8 cm.[7] These results suggest that the assumption of the universal safety of the lateral port insertion zone is not valid.
Although the incidence of vascular complications during laparoscopy is low, it still has clinical significance. According to a 2025 review, the overall incidence of vascular complications in gynecological laparoscopy was between 0.04–0.5%. The inferior epigastric vessels are a particularly vulnerable vascular region when performing a lateral laparotomy.[2] In addition, in 2023, one surgical report found that injury to the vessels ranged from 1–6 per 1,000 laparoscopic procedures and noted that intraoperatively, bleeding into the abdominal wall may go undetected because the pneumoperitoneum compresses the injured vessels for a short period.[8] As a result, a patient can suffer delayed port site hematoma, ecchymosis, or infection, or may need to undergo further intervention.[9] These findings suggest that port site complications may be affected not only by the surgical technique and the characteristics of the trocar used, but also by individual differences in abdominal wall vascular anatomy.[10]
While the new laparoscopic techniques are becoming more and more precise and safer, it should not be overlooked that anatomical variations of the inferior epigastric vessels are another potentially preventable factor that can contribute to port site complications. The knowledge of specific vascular patterns associated with higher postoperative morbidity could give clinically relevant information for individualized placement of trocars, pre-operative risk assessment, and safer surgical planning. Furthermore, the anatomical-clinical relationship may help to fill the gap between the descriptive vascular anatomy and its use in minimally invasive surgery. The present study aimed to compare the frequency and pattern of port-site complications among patients with various anatomical variations of the inferior epigastric vessels following laparoscopic abdominal surgery and to assess the correlation of such variations with the rate of subsequent port-site complications.
The minimally invasive nature of the procedure, as well as the fact that its postoperative period is characterized by a lesser degree of pain, is shorter in length than that of open surgery, and the time of recovery is shorter, has led to the use of laparoscopic abdominal surgery in modern surgical practice.[1] Despite these benefits, the insertion of the trocar is still a key step that has been linked with disruption of the vascular structures, especially the inferior epigastric vessels. These are significant blood supply vessels and should be avoided at the time of secondary laparoscopic port placement.[2] In 2021, an extensive review was published reporting that 48% (95% CI: 40–55%) of all vascular injuries were described in inferior epigastric vessels in laparoscopic and robotic-assisted procedures.[3] These injuries can lead to port-site bleeding, abdominal wall hematoma, postoperative pain, and even substantial bleeding that requires surgical intervention.[4]
The inferior epigastric artery usually runs on the back of the rectus abdominis muscle and, with its veins, travels from the external iliac artery at the level of the inguinal ligament.[5] There is a lot of anatomical variation, however, in the course, branching pattern, lateral displacement, and relationship of these vessels to known abdominal landmarks.[6] In a recent anatomical mapping review published in 2026, significant anatomical variations in the distance of the inferior epigastric artery from the abdominal midline were found, with interstudy distances from the abdominal midline reported by different studies from 3 to 8 cm.[7] These results suggest that the assumption of the universal safety of the lateral port insertion zone is not valid.
Although the incidence of vascular complications during
laparoscopy is low, it still has clinical significance. According to a 2025 review, the overall incidence of vascular complications in gynecological laparoscopy was between 0.04–0.5%. The inferior epigastric vessels are a particularly vulnerable vascular region when performing a lateral laparotomy.[2] In addition, in 2023, one surgical report found that injury to the vessels ranged from 1–6 per 1,000 laparoscopic procedures and noted that intraoperatively, bleeding into the abdominal wall may go undetected because the pneumoperitoneum compresses the injured vessels for a short period.[8] As a result, a patient can suffer delayed port site hematoma, ecchymosis, or infection, or may need to undergo further intervention.[9] These findings suggest that port site complications may be affected not only by the surgical technique and the characteristics of the trocar used, but also by individual differences in abdominal wall vascular anatomy.[10]
While the new laparoscopic techniques are becoming more and more precise and safer, it should not be overlooked that anatomical variations of the inferior epigastric vessels are another potentially preventable factor that can contribute to port site complications. The knowledge of specific vascular patterns associated with higher postoperative morbidity could give clinically relevant information for individualized placement of trocars, pre-operative risk assessment, and safer surgical planning. Furthermore, the anatomical-clinical relationship may help to fill the gap between the descriptive vascular anatomy and its use in minimally invasive surgery. The present study aimed to compare the frequency and pattern of port-site complications among patients with various anatomical variations of the inferior epigastric vessels following laparoscopic abdominal surgery and to assess the correlation of such variations with the rate of subsequent port-site complications..
In the present study, 105 patients with a typical inferior epigastric vascular anatomy and 46 with anatomical variations were included in the final analysis of patients undergoing laparoscopy in the abdomen. Demographic and clinical features were similar between the two groups, with no statistically significant difference in age, sex, BMI, diabetes mellitus, hypertension, or previous abdominal surgery (all p>0.05) (Table 1).
Pre-operatively, Doppler ultrasonography revealed that there were significant differences in distance between the vessels and midline at both the umbilicus and suprapubic level between the two anatomical groups. The patients with variants in vascular anatomy also had a significantly higher rate of vessels within 1 cm of the planned trocar insertion site (p<0.001). The main anatomical differences found were lateral displacement, atypical branching, and right–left asymmetry (Table 2).
The operative characteristics were all comparable among groups, and there were no significant differences in any of the following: type of surgery, number of ports, size of the port, or whether the port was placed laterally in the lower quadrant (all p > 0.05). Bleeding at the port site during surgery was, however, significantly more common in patients with variant vascular anatomy (p=0.046) (Table 3).
Patients with anatomical variations had significantly more port-site complications than those with typical vascular anatomy (p=0.048). Similarly, intraoperative bleeding showed a similar association, while postoperative hematoma, ecchymosis, infection, persistent pain, and further hemostatic intervention did not significantly differ between the groups (all p > 0.05) (Table 4).
The differences in the port-site complications were analyzed by comparing patients with typical and variant inferior epigastric vascular anatomy. The associations were analyzed with appropriate statistical tests, and odds ratios and 95% CIs were calculated to estimate the size of any observed difference (Table 5).
Anatomical variations of the inferior epigastric vessels were associated with increased odds of port-site complications (aOR = 3.42; 95% CI: 1.21–9.67; p = 0.020) in the multivariable logistic regression model. Also, higher BMI (aOR = 1.12, p = 0.034) and lateral placement of trocars (aOR = 2.76, p = 0.042) were shown to have statistically significant associations. Complications were not significantly related to age, sex, or type of surgery after adjustment (Table 6).
Table 1. Baseline Demographic and Clinical Characteristics
|
Characteristic |
Total (N=151) |
Typical (n=105) |
Variant (n=46) |
p-value |
|
Age, years, mean ± SD |
42.8 ± 13.1 |
42.1 ± 12.8 |
44.4 ± 13.8 |
0.338 |
|
Age group |
|
|
|
0.754 |
|
18–39 years |
66 (43.7%) |
48 (45.7%) |
18 (39.1%) |
|
|
40–59 years |
61 (40.4%) |
41 (39.0%) |
20 (43.5%) |
|
|
≥60 years |
24 (15.9%) |
16 (15.2%) |
8 (17.4%) |
|
|
Sex |
|
|
|
0.857 |
|
Female |
91 (60.3%) |
64 (61.0%) |
27 (58.7%) |
|
|
Male |
60 (39.7%) |
41 (39.0%) |
19 (41.3%) |
|
|
BMI, kg/m², mean ± SD |
26.5 ± 4.2 |
26.2 ± 4.1 |
27.2 ± 4.4 |
0.193 |
|
Diabetes mellitus |
28 (18.5%) |
18 (17.1%) |
10 (21.7%) |
0.503 |
|
Hypertension |
35 (23.2%) |
23 (21.9%) |
12 (26.1%) |
0.676 |
|
Previous minor abdominal surgery |
24 (15.9%) |
15 (14.3%) |
9 (19.6%) |
0.470 |
Table 2. Preoperative Doppler Anatomical Mapping
|
Vascular characteristic |
Typical (n=105) |
Variant (n=46) |
Total (N=151) |
p-value |
|
Typical course, no branching anomaly |
105 (100%) |
0 |
105 (69.5%) |
N/A |
|
Lateral displacement of course |
0 |
20 (43.5%) |
20 (13.2%) |
N/A |
|
Early/atypical branching |
0 |
14 (30.4%) |
14 (9.3%) |
N/A |
|
Asymmetric right–left course |
0 |
12 (26.1%) |
12 (7.9%) |
N/A |
|
Right vessel distance at umbilical level, cm |
4.9 ± 0.7 |
5.8 ± 1.0 |
5.2 ± 0.9 |
<0.001 |
|
Left vessel distance at umbilical level, cm |
5.0 ± 0.7 |
5.7 ± 1.1 |
5.2 ± 0.9 |
<0.001 |
|
Right distance at suprapubic level, cm |
6.2 ± 0.8 |
6.8 ± 1.0 |
6.4 ± 0.9 |
<0.001 |
|
Left distance at suprapubic level, cm |
6.3 ± 0.8 |
6.9 ± 1.1 |
6.5 ± 0.9 |
0.001 |
|
Vessel within 1 cm of planned port |
12 (11.4%) |
19 (41.3%) |
31 (20.5%) |
<0.001 |
Table 3. Operative and Trocar Characteristics
|
Operative variable |
Typical (n=105) |
Variant (n=46) |
Total (N=151) |
p-value |
|
Type of surgery |
|
|
|
0.922 |
|
Laparoscopic cholecystectomy |
65 (61.9%) |
27 (58.7%) |
92 (60.9%) |
|
|
Laparoscopic appendectomy |
24 (22.9%) |
11 (23.9%) |
35 (23.2%) |
|
|
Laparoscopic hernia repair |
16 (15.2%) |
8 (17.4%) |
24 (15.9%) |
|
|
Number of ports |
|
|
|
0.853 |
|
Three ports |
37 (35.2%) |
15 (32.6%) |
52 (34.4%) |
|
|
Four ports |
68 (64.8%) |
31 (67.4%) |
99 (65.6%) |
|
|
At least one 5-mm secondary port |
105 (100%) |
46 (100%) |
151 (100%) |
N/A |
|
At least one 10–12-mm secondary port |
40 (38.1%) |
19 (41.3%) |
59 (39.1%) |
0.721 |
|
Lateral lower-quadrant secondary port |
55 (52.4%) |
26 (56.5%) |
81 (53.6%) |
0.724 |
|
Intraoperative port-site bleeding |
5 (4.8%) |
7 (15.2%) |
12 (7.9%) |
0.046 |
Table 4. Port-Site Complications During Surgery and Within 30 Days
|
Outcome |
Typical (n=105) |
Variant (n=46) |
Total (N=151) |
p-value |
|
Any port-site complication |
8 (7.6%) |
9 (19.6%) |
17 (11.3%) |
0.048 |
|
Intraoperative port-site bleeding |
5 (4.8%) |
7 (15.2%) |
12 (7.9%) |
0.046 |
|
Postoperative hematoma |
3 (2.9%) |
5 (10.9%) |
8 (5.3%) |
0.057 |
|
Ecchymosis |
3 (2.9%) |
4 (8.7%) |
7 (4.6%) |
0.201 |
|
Port-site infection |
2 (1.9%) |
2 (4.3%) |
4 (2.6%) |
0.586 |
|
Persistent port-site pain |
2 (1.9%) |
3 (6.5%) |
5 (3.3%) |
0.166 |
|
Additional hemostatic intervention |
1 (1.0%) |
2 (4.3%) |
3 (2.0%) |
0.220 |
|
No port-site complication |
97 (92.4%) |
37 (80.4%) |
134 (88.7%) |
0.048 |
Table 5. Unadjusted comparisons of anatomical patterns and complications
|
Comparison |
Typical |
Variant |
OR (95% CI /p-value) |
|
Any complication |
8/105 (7.6%) |
9/46 (19.6%) |
2.95 (1.06- 8.22); p=0.048 |
|
Intraoperative bleeding |
5/105 (4.8%) |
7/46 (15.2%) |
0.046 |
|
Postoperative hematoma |
3/105 (2.9%) |
5/46 (10.9%) |
0.057 |
|
Vessel within 1 cm of port |
12/105 (11.4%) |
19/46 (41.3%) |
0.000 |
Table 6. Multivariable Logistic Regression Analysis of Factors Associated with Port-Site Complications Following Laparoscopic Abdominal Surgery (n = 151)
|
Variables |
Adjusted OR |
95% CI |
p-value |
|
Anatomical variation of inferior epigastric vessels (present vs absent) |
3.42 |
1.21–9.67 |
0.020 |
|
Age (per year increase) |
1.03 |
0.98–1.08 |
0.241 |
|
Sex (male vs female) |
1.28 |
0.46–3.56 |
0.637 |
|
BMI (per kg/m² increase) |
1.12 |
1.01–1.25 |
0.034 |
|
Type of surgery (laparoscopic cholecystectomy vs other procedures) |
0.84 |
0.29–2.43 |
0.748 |
|
Trocar location (lateral vs non-lateral) |
2.76 |
1.04–7.33 |
0.042 |
The present study was designed to investigate the correlation between anatomical variation of the inferior epigastric vessels and port site complications after laparoscopy in the abdomen. Higher BMI, lateral placement of the trocar, and anatomical variation were statistically significant in the multivariable analysis, with increased odds of port-site complications associated with anatomical variation (p = 0.020). The results of these findings indicated that there might be a potential association between vascular anatomy and port site morbidity, but causality could not be determined because of the cross-sectional design. In an ultrasonographic study of 61 patients, Gan et al. (2023) reported that the inferior
epigastric arteries were found at an average distance of 3.5–8 cm from the abdominal midline, and there were significant differences in the distances between the right and left sides.[11] They were able to confirm the presence of clinically relevant anatomical variation and were not able to demonstrate a direct link between the anatomical variation and postoperative complications.[11]
The anatomical findings were also well in line with those of Le Saint-Grant et al. (2021), who analysed the anterior abdominal wall arteries using ultrasonography in 24 subjects.[12] The investigators confirmed the change in position and depth of the epigastric arteries with changing levels in the abdomen, noting that the arteries tended to run more medially the more superior in the abdomen. Their results emphasized the need to take into account the position of the vessels in the abdominal wall when instrumenting it. A similar study of 90 children in 2026 using Doppler ultrasonography found differences between the distance from one vessel to the other at various levels in the abdomen, with mean distances of about 4.64 cm between the vessels at the level of the umbilicus and 6.18–6.46 cm near the pubic symphysis.[13] The reported studies provide confirmatory evidence for the anatomical basis of the present investigation, but direct numerical comparisons were hindered by some differences in the age of the patients examined, anatomical measurements, and the study populations.
The anatomical plausibility of the association between lateral trocar placement and port-site complications (aOR = 2.76; 95% CI, 1.04–7.33; p = 0.042) could be explained by the fact that secondary ports could cross over areas where the inferior epigastric vessels are present. According to Garunyapakun et al. (2026), a review of the anatomical and imaging evidence, a vascular danger zone is commonly found about 4–8 cm to the lateral side of the midline; however, there is significant inter-individual variability.[14] The findings indicated that careful consideration of the trocar placement was warranted instead of a set distance from the midline. However, the review did not offer prospective evidence that either a specific strategy for port placement reduced the number of postoperative complications, and this association should, therefore, be read with caution.
Higher BMI was associated with complications at the port site (aOR = 1.12; 95% CI: 1.01-1.25; p = 0.034), suggesting the potential for patient-related effects on procedural difficulty. The strength of this relationship, however, was modest, and results should be interpreted with caution. In a computed tomography angiography study of 75 patients and 142 evaluable abdominal sides, Szafarenko et al. (2026) found significant differences in the origin and branching pattern of the inferior epigastric artery. In 77.5% of the sides examined, the artery had its origin from the external iliac artery, 15.5% from a common trunk with the obturator artery, and the rest from other arteries. This study was designed to further investigate anatomical heterogeneity but did not directly assess port-site complications associated with BMI.[15]
The significance of umbilical and epigastric gallbladder retrieval sites was further confirmed by Sadaf et al. (2026), who performed a comparison study of 114 laparo-chole patients. The adjusted odds of developing infection at the port site were 14.9% in all patients and were statistically significantly lower for patients undergoing umbilical retrieval than for those undergoing epigastric retrieval (p=0.021).[16] This study confirmed that port-site characteristics were relevant to the postoperative results; the results were for specimen retrieval and infection, not actual inferior epigastric vessel injury. Thus, it offered only indirect evidence, not confirmation, for the present relationship with lateral trocar placement.
Inferior epigastric vessel injury, which can result in clinical consequences, was depicted by Faulkner et al. (2023) when they reported a 68-year-old patient who underwent laparoscopic appendectomy and developed a pseudoaneurysm in the 4.2 cm inferior epigastric artery. The complication occurred about 2 weeks after surgery and required surgery to remedy it.[17] Likewise, a 2021 case report reported injury to the inferior epigastric vessels when inserting a 2 mm trocar in a child undergoing laparoscopic inguinal hernia repair, and control of the bleeding using Foley catheter tamponade.[18] These reports pointed out that vascular complications potentially could be clinically significant even with small trocars. Perioperative complications, however, could not be determined on an individual case basis and could not be quantified as a risk factor associated with anatomical variations.
Kuo et al. (2025) studied the superficial inferior epigastric and superficial circumflex iliac vascular systems by ultra-high-frequency ultrasonography to support the potential value of preoperative vascular evaluation. They have shown the benefit of detailed imaging in reconstructive surgical planning of lower abdominal vascular structures in this study. The superficial inferior epigastric system was not anatomically the same as the inferior epigastric vessels studied in the present study, but the results showed a greater overall feasibility of vascular imaging in an individual. They did not, however, prove that vascular injuries or other port-site complications were reduced by routine Doppler mapping before laparoscopic surgery.[19]
In general, the literature reviewed indicated that there is a significant amount of anatomic variation in the inferior epigastric vessels and that there is a clinical relevance to vascular injury caused by the placement of trocars. Most studies centered on anatomical mapping, general port site morbidity, or specific vascular complications, and did not directly compare the postoperative results of patients with typical and variant vascular anatomy. The present results indicated a clinically relevant association and not an independent causal factor of anatomical variation. Relatively few events related to complications may have also reduced the reliability of the adjusted estimates, and there may have been variations in the surgical procedure. A larger prospective study with a standardised Doppler assessment, with well-defined vascular complications and appropriate adjustment of the procedure factors would be needed to assess whether there is any meaningful relationship between anatomical variations and port-site morbidity.
Limitations
There were several limitations of the study. The study was a single-center, comparative cross-sectional study, which restricted the generalizability of the results and the making of causal inferences. The relatively small number of participants and possibly the smaller number of vascular complications were associated with less statistical power and precision of the adjusted estimates. Vascular anatomy was assessed by color Doppler ultrasonography, but this method has inherent measurement bias, and the difficulty of visualizing smaller vascular branches may also have caused measurement bias. The rates of complications may have been influenced by variations in surgical techniques, trocar positioning, or surgeon experience. In addition, the number of postoperative follow-up visits might have been too short to fully assess delayed complications.
Anatomical variations of the inferior epigastric vessels may be associated with an increased likelihood of port-site complications following laparoscopic abdominal surgery. The morbidity after the operation can be increased also by a higher BMI and a lateral position of the trocar. The results of these studies show that individualized vascular evaluation and careful positioning of trocars may be of clinical significance. However, larger prospective multi-center studies are required to confirm these relationships and to establish whether or not preoperative vascular mapping can decrease port-site complications.